Verify that the port or interface is not disabled or for some reason powered off. Make sure that all you have properly cleaned and securely connected all fiber-optic connections.Īn obvious but sometimes overlooked cause of port con nectivity failure is a disabled port.Use the show interfaces privileged EXEC command to verify the port or module error-disabled, disabled, or shutdown status.See the “Features” section for a list of supported SFP modules. Verify that this module supports this platform. Exchange the suspect module with a known, good module. This encoding provides a way for Cisco to identify and validate that the module meets the requirements for the switch.
Cisco 2950 switch oringe light flashing serial#
Each Cisco module has an internal serial EEPROM that is encoded with security information. Use only Cisco small form-factor (SFP) modules on the switch. Sometimes a cable appears to be seated, but is not. See Appendix B, “Connector and Cable Specifications.” for more information. Verify that you are using the correct cable type.Make sure that both ends of the cable are connected to the correct ports.Connect the cable from the switch to a known, good device.If the link light for the port does not come on: The cable might have encountered physical stress that causes it to function at a marginal level. A single broken wire or one sh utdown port can cause one side to show link, but the other side does not have link.Ī link LED does not guarantee that the cable is fully functional. Enable auto-MDIX on the switch, or replace the cable. For copper connections, determine if a crossover cable was used when a straight-through cable was required or the reverse.For more information about cabling, see Appendix B, “Connector and Cable Specifications.” Make sure that the ports on the connected device match and that they use the same type of encoding, optical frequency, and fiber type. For fiber-optic connectors, verify that you have the correct cable for the distance and port type.Use either Category 5, Category 5e, or Category 6 UTP for 10/100 or 10/100/1000 Mb/s connections. For Ethernet, use Category 3 copper cable for 10 Mb/s unshielded twisted pair (UTP) connections.Make sure that you have the correct cable ty pe for the connection: Try using the cable in another port or interface to see if the problem also exists there.
Cisco 2950 switch oringe light flashing Patch#
If possible, bypass the patch panel or eliminate faulty media convertors, such as fiber-optic-to-copper convertors. Rule out any insufficient patch panel connections or media convertors between the source and the destination.Look for broken or missing pins on cable connectors.Change the copper or fiber-optic cable with a known, good cable if necessary.You can identify this situation because the port will have many packet errors, or the port constantly loses and regains link. A cable might connect at the physical layer but then cause packet corruption because of subtle damage to its wiring or connectors. Review these sections when troubleshooting switch co nnectivity problems:Īlways look at the cable for marginal da mage or failure. See the “LEDs” section for a description of the LED colors and their meanings. Look at the port LEDs for troubleshooting information about the switch. Conta ct your Cisco technical support representative if your switch does not pass POST. If POST completes successfully, the system LED rapidly blinks green. If POST fails, the system LED remains amber. When POST completes, the system LED blinks amber. When the switch begins POST, the system LED slowly blinks green. It might take several minutes for the switch to complete POST.
Cisco 2950 switch oringe light flashing software#
See the software configuration guide and the switch command reference on or the documentation that came with your SNMP application for more information.Īs the switch powers on, it begins the POST, a series of tests that runs automatically to ensure that the switch functions properly. You can also get statistics from the CLI or from an SNMP workstation. They show POST failures, port-connectivity problems, and overall switch performance. The L EDs on the front panel provide trouble shooting information about the switch.
Cisco 2950 switch oringe light flashing full#
For a full description of the switch LEDs, see the “LEDs” section. They show failures in the power-on self-test ( POST), port-connectivity problems, and overall switch performance. The LEDs on the front panel provide troubleshooting information about the switch.